EJOT® JC2-IT Plus
Specification
-
Applications
- ETA-approved concrete screw for cracked and uncracked concrete
- Suitable for dry indoor conditions
- Fastening of e.g.:
- Pipe brackets
- Profile rails
-
Properties
- Zinc-plated steel
- Hexagon head SW13 with internal thread M8/M10
- Self-tapping approved screw anchor for push-in installation
- No expansion therefore small edge and centre distances possible
- Completely removable
- Fire resistant
- Suitablity according to seismic performance category C2000
- ETA-Approval ETA-17/1009 and ETA-20/0446 Option 1
-
Base materials:
Approved for - Cracked concrete
- Non-cracked concrete
- Pre-stressed hollow core slab
-
Notice
Please refer to the product data sheet in the Downloads section for the allowable loads for cracked and uncracked concrete.
-
Embedment substrates
- Drive: Hexagon SW13
- Threaded pin diameter: M8/M10
- Drill hole diameter: 6.0
- Tightening torque Tinst: max. 14 Nm
- Diameter head: 14.0 mm
Filter
Selected filters
| Orderidentifier | Article Number | ø mm | Length mm | Drill hole depth mm | Pilot Hole Ø d0≥ mm | Unit |
|---|---|---|---|---|---|---|
| JC2-IT 6X35 M8/M10x30 | 9650071513 | 6.0 | 35.0 | 40.0 | 6.0 | 50 |
Specifications
|
||||||
| JC2-IT 6X45 M8/M10x30 | 9650071514 | 6.0 | 45.0 | 50.0 | 6.0 | 50 |
Specifications
|
||||||
| JC2-IT 6X60 M8/M10x30 | 9650071519 | 6.0 | 60.0 | 65.0 | 6.0 | 50 |
Specifications
|
||||||
| JC2-IT 6x35 M8/M10x30 ZA | 9650071524 | 6.0 | 6.0 | 50 | ||
Specifications
|
CAD
* Thank you for your interest in our CAD data. To be able to use this area, simply log in or please register here.
CAD & more - Your Online Service Area
Unfortunately you currently have no authorization to use "CAD & more".
Unfortunately, this data can not be provided to you without the consent of the confidentiality agreement.
Your request will be manually verified, this can take 1 to 3 business days.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Grant Access to CAD Data
Unfortunately you currently have no authorization to use "CAD & more".
Apply for access to CAD data.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Thank you!
Your request will be manually verified, this may take 1 to 3 business days.
You will receive an e-mail as soon as your access for "CAD & more" has been activated.
Thank you for your patience.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Confirm CAD data renewal
In the e-mail sent by us you will find the link to verify your account, please click on it.
If you do not receive an e-mail within a few minutes, please check your spam folder.
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Can not be renewed
Please contact our customer care
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com
Can not process your request for CAD
Please contact our customer care
-
For technical questions please contact our Hotline Team +49 2751 529-123
Problems with your access? Mail to: service-industrie@ejot.com