EJOT® facade anchor SDF-KB-14A

Specification

  • Applications

    • Installation of metal attachments
    • For multiple fastening of non-load-bearing systems according to EAD 330284
    • Suitable for the structural fastening of wall cupboards, cladding, metal angle pieces
  • Properties

    • Hexagon head with flange
    • Approved for all common building materials
    • Reliable hold in problematic building materials thanks to optimised expansion part
    • Radial expansion for reliable hold
    • Product identification through different sleeve colours
    • Double safety lock against torsion for secure installation

    Base materials
    Approved for

    • Cracked concrete
    • Non-cracked concrete
    • Solid masonry
    • Hollow and perforated bricks
    • Aerated concrete

    Note
    For planning, please observe approval ETA-15/0027. For bricks of unknown quality, the load-bearing capacity must be determined through pull-out tests on the structure. When used in concrete, a silicone lubricant paste (e.g. FUCHS CHEMPLEX SI-LK 2) and the use of an impact screwdriver with particularly high torque are recommended

  • Technical specifications

    Characteristic values

    • Diameter: 14 mm
    • Drive: Hexagon A/F17
    • Drill hole depth ≥ t: 80 mm
    • Embedment depth ≥ hv: 70 mm 

    Permitted load*

    • Tensile load NRk,pin concrete > C12/15: 3.37 kN
    • Brick Mz 20-1,8, NF: 1.57 kN
    • Solid lime sand brick KS, 2 DF 20-2,0: 1.71 kN
    • Solid lime sand brick KS, 8 DF 20-1,8: 2.00 kN
    • Solid brick V, 3 DF: 0.86 kN
    • Vertically perforated brick HLz, 2 DF 28-1.2: 0.57 kN
    • Perforated sand-lime brick KSL, 8 DF 16-1.4: 0.71 kN
    • Cavity block tile made of lightweight concrete Hbl, 12 DF: 0.71 kN
    • Aerated concrete fCK ≥ 2 N/ mm2: 0.43 kN
    • Aerated concrete fCK ≥ 4 N/ mm2: 0.89 kN
    • Aerated concrete fCK ≥ 6 N/ mm2: 1.60 kN
    • Transverse load VRk,s
      • Steel screw (γMs = 1.25): 17.4 kN 
      • Stainless steel screw (γMs = 1.56): 16.2 kN
    • Bending moment MRk,s
      • Steel screw (γMs = 1.25): 50.0 Nm
      • Stainless steel screw (γMs = 1.56): 46.7 Nm

     *applies to temperature range 30-50 oC / 50-80 oC

Filter

Selected filters

    Orderidentifier Article Number ø mm Material Anchor length mm Clamping thickness

    tfix≤ mm

    Unit
    SDF-KB-14Ax80-V 8590080430 14.0 Carbon Steel 80.0 10.0 50

    Specifications

    ø
    14.0
    Material
    Carbon Steel
    Anchor length
    80.0
    Clamping thickness

    tfix

    10.0
    Orderidentifier
    SDF-KB-14Ax80-V
    Unit
    50
    SDF-KB-14Ax100-V 8590100430 14.0 Carbon Steel 100.0 30.0 50

    Specifications

    ø
    14.0
    Material
    Carbon Steel
    Anchor length
    100.0
    Clamping thickness

    tfix

    30.0
    Orderidentifier
    SDF-KB-14Ax100-V
    Unit
    50

    CAD

    * Thank you for your interest in our CAD data. To be able to use this area, simply log in or please register here.

    CAD & more - Your Online Service Area

    Unfortunately you currently have no authorization to use "CAD & more".

    Unfortunately, this data can not be provided to you without the consent of the confidentiality agreement.
    Your request will be manually verified, this can take 1 to 3 business days.

    • For technical questions please contact our Hotline Team +49 2751 529-123
      Problems with your access? Mail to: service-industrie@ejot.com

    Grant Access to CAD Data

    Unfortunately you currently have no authorization to use "CAD & more".

    Apply for access to CAD data.

    CAD & More

    "CAD & More" provides you with confidential information about our products DELTA PT®, ALtracs® Plus, SHEETtracs® (CAD files, product files, drawings etc.). This data can only be accessed by customers of the EJOT Industrial Division and will not be made


    • For technical questions please contact our Hotline Team +49 2751 529-123
      Problems with your access? Mail to: service-industrie@ejot.com

    Thank you!

    Your request will be manually verified, this may take 1 to 3 business days.
    You will receive an e-mail as soon as your access for "CAD & more" has been activated.
    Thank you for your patience.



    • For technical questions please contact our Hotline Team +49 2751 529-123
      Problems with your access? Mail to: service-industrie@ejot.com

    Confirm CAD data renewal

    In the e-mail sent by us you will find the link to verify your account, please click on it.
    If you do not receive an e-mail within a few minutes, please check your spam folder.



    • For technical questions please contact our Hotline Team +49 2751 529-123
      Problems with your access? Mail to: service-industrie@ejot.com

    Can not be renewed

    Please contact our customer care



    • For technical questions please contact our Hotline Team +49 2751 529-123
      Problems with your access? Mail to: service-industrie@ejot.com

    Can not process your request for CAD

    Please contact our customer care



    • For technical questions please contact our Hotline Team +49 2751 529-123
      Problems with your access? Mail to: service-industrie@ejot.com