ejotherm NT U - Technical characteristics



 
 
 
Technical data

anchor diameter           8 mm
plate diameter 60 mm
drill hole depth h1 35 mm
anchorage depth hef 25 mm
use categories acc. to ETA A, B, C
European Technical Approval ETA-05/0009


 

approved for concrete, solid
and perforated masonry
 

Characteristic loads

concrete C 12/15 acc. to. EN 206-1 1.2 kN
concrete C 16/20 - C 50/60 acc. to EN 206-1 1.2 kN
clay brick (Mz) acc. to DIN 105 1.5 kN
solid lime sandstone (KS) acc. to DIN EN 106 1.5 kN
solid bricks of lightweight concrete (V) acc. to DIN 18152 0.5 kN
vertical coring brick (Hlz) acc. to DIN 105 0.9 kN
perforated lime sandstone (KSL) acc. to DIN EN 106 1.5 kN
hollow block of lightweight concrete (HbL) acc. DIN 18151 0.5 kN

Regarding design loads the national safety factors are to be incorporated
(e.g. Germany: 3). Please observe the approval.