EJOT® Universal anchor SDF-KB-10H
 
       
       
       
      
Specification
- 
            Applications- Installation of metal attachments
- For multiple fastening of non-load-bearing systems according to EAD 330284-00-0604
- Suitable for the structural fastening of wall cupboards, cladding, metal angle pieces
- For embedment in rain screens
- For application as single fastening in concrete
 
- 
            Properties- Hexagon head with flange
- Approved for all common building materials
- Reliable hold in problematic building material thanks to optimised expansion part
- Radial expansion for reliable hold
- Product identification through different sleeve colours
- Double safety lock against torsion for secure installation
 Base materials 
 Approved for- Cracked concrete
- Non-cracked concrete
- Solid masonry
- Hollow and perforated bricks
- Aerated concrete
 Note 
 For planning and processing, please observe ETA-10/0305 and Z-21.2-2122. Further information about parameters and loads can be found in the approvals. For bricks of unknown quality, the load-bearing capacity must be determined through pull-out tests on the structure.
- 
            Technical specificationsCharacteristic values - Diameter: 10 mm
- Hole depth in concrete h1.1: ≥ 80 mm
- Effective embedment depth hnom: ≥ 70 mm
- Drill hole diameter d0: 10 mm
- Through hole diameter of component to be attached df: ≤ 10.5 mm
- Drive: AF13/T40
 Admissible loads - Tensile load NRk,p in concrete C12/15
	- Temperature range 30 °C / 50 °C: 1.79 kN
- Temperature range 50 °C / 80 °C: 1.59 kN
 
- Brick Mz 20-1.8, NF: 1.14 kN
- Solid sand-lime brick KS 36, NF: 1.29 kN
- Solid sand-lime brick KS 20, 8 DF: 1.29 kN
- Solid lightweight concrete brick V6, 2 DF: 0.57 kN
- Vertically perforated brick HLz 12-0.9, NF: 0.57 kN
- Perforated sand-lime brick KSL 12, 4 DF: 0.71 kN
- Cavity block made of lightweight concrete Hbl 10, 12 DF: 0.34 kN
- Transverse load VRk,s
	- Steel screw (γMs = 1.25): 7.48 kN
- Stainless steel screw (γMs = 1.56) 6.99 kN
 
- Bending moment MRk,s
	- Steel screw (γMs = 1.25): 14.14 kN
- Stainless steel screw (γMs = 1.56): 13.22 kN
 
- Compressive strength aerated concrete [N/mm2]: 30 - 50 °C
 Aerated concrete fb ≥ 4 N/mm2: 0.54 kN
 Aerated concrete fb ≥ 5 N/mm2: 0.71 kN
 Aerated concrete fb ≥ 6 N/mm2: 0.89 kN
 Aerated concrete fb ≥ 7 N/mm2: 0.89 kN
 
Further lengths available upon request
Filter
Selected filters
| Orderidentifier | Article Number | ø mm | Material | Length mm | Clamping thickness tfix≤ mm | Unit | 
|---|---|---|---|---|---|---|
| SDF-KB-10Hx80-V | 8513080420 | 10.0 | Carbon Steel | 80.0 | 10.0 | 100 | 
| Specifications
 | ||||||
| SDF-KB-10Hx80-E | 8513080620 | 10.0 | Stainless Steel | 80.0 | 10.0 | 100 | 
| Specifications
 | ||||||
| SDF-KB-10Hx100-V | 8513100420 | 10.0 | Carbon Steel | 100.0 | 30.0 | 50 | 
| Specifications
 | ||||||
| SDF-KB-10Hx100-E | 8513100620 | 10.0 | Stainless Steel | 100.0 | 30.0 | 50 | 
| Specifications
 | ||||||
| SDF-KB-10Hx120-V | 8513120420 | 10.0 | Carbon Steel | 120.0 | 50.0 | 50 | 
| Specifications
 | ||||||
| SDF-KB-10Hx120-E | 8513120620 | 10.0 | Stainless Steel | 120.0 | 50.0 | 50 | 
| Specifications
 | ||||||
| SDF-KB-10Hx140-V | 8513140420 | 10.0 | Carbon Steel | 140.0 | 70.0 | 50 | 
| Specifications
 | ||||||
| SDF-KB-10Hx140-E | 8513140620 | 10.0 | Stainless Steel | 140.0 | 70.0 | 50 | 
| Specifications
 | 
CAD
* Thank you for your interest in our CAD data. To be able to use this area, simply log in or please register here.
CAD & more - Your Online Service Area
Unfortunately you currently have no authorization to use "CAD & more".
  Unfortunately, this data can not be provided to you without the consent of the confidentiality agreement. 
Your request will be manually verified, this can take 1 to 3 business days.
- 
        
        For technical questions please contact our Hotline Team +49 2751 529-123
 Problems with your access? Mail to: service-industrie@ejot.com
Grant Access to CAD Data
Unfortunately you currently have no authorization to use "CAD & more".
Apply for access to CAD data.
- 
      
      For technical questions please contact our Hotline Team +49 2751 529-123
 Problems with your access? Mail to: service-industrie@ejot.com
Thank you!
    Your request will be manually verified, this may take 1 to 3 business days. 
You will receive an e-mail as soon as your access for "CAD & more" has been activated. 
Thank you for your patience.
  
- 
      
      For technical questions please contact our Hotline Team +49 2751 529-123
 Problems with your access? Mail to: service-industrie@ejot.com
Confirm CAD data renewal
            In the e-mail sent by us you will find the link to verify your account, please click on it.
 If you do not receive an e-mail within a few minutes, please check your spam folder.
          
- 
      
      For technical questions please contact our Hotline Team +49 2751 529-123
 Problems with your access? Mail to: service-industrie@ejot.com
Can not be renewed
Please contact our customer care
- 
      
      For technical questions please contact our Hotline Team +49 2751 529-123
 Problems with your access? Mail to: service-industrie@ejot.com
Can not process your request for CAD
Please contact our customer care
- 
        
        For technical questions please contact our Hotline Team +49 2751 529-123
 Problems with your access? Mail to: service-industrie@ejot.com

 
       
       
   
   
   
   
   
  ![[socket_wrench_insert].png](/medias/sys_master/products/products/h76/hcc/9004086263838/-socket-wrench-insert-135Wx135H.png) 
  